HEIDENHAIN TNC 620 (81760x-02) ISO programming User Manual
Page 460

Manual operation and setup
14.6 Datum setting without a 3-D touch probe
14
460
TNC 620 | User's ManualDIN/ISO Programming | 2/2015
Using touch probe functions with mechanical
probes or measuring dials
If you do not have an electronic 3-D touch probe on your machine,
you can also use all the previously described manual touch probe
functions (exception: calibration function) with mechanical probes
or by simply touching the workpiece with the tool, see page 461.
In place of the electronic signal generated automatically by a
3-D touch probe during probing, you can manually initiate the
trigger signal for capturing the
probing position
by pressing a key.
Proceed as follows:
Select any touch probe function by soft key
Move the mechanical probe to the first position to
be captured by the TNC
Confirm the position: Press the actual-position-
capture soft key for the TNC to save the current
position
Move the mechanical probe to the next position to
be captured by the TNC
Confirm the position: Press the actual-position-
capture soft key for the TNC to save the current
position
If required, move to additional positions and
capture as described previously
Datum: In the menu window, enter the
coordinates of the new datum, confirm with the
SET DATUM soft key, or write the values to a table
(see "Writing measured values from the touch
probe cycles in a datum table", page 466, or see
"Writing measured values from the touch probe
cycles in the preset table", page 467)
Terminate the probing function: Press the
END key