Datum management with the preset table 14.5 – HEIDENHAIN TNC 620 (81760x-02) ISO programming User Manual
Page 453

Datum management with the preset table 14.5
14
TNC 620 | User's ManualDIN/ISO Programming | 2/2015
453
Manually saving the datums in the preset table
In order to save datums in the preset table, proceed as follows:
Select the
Manual Operation mode
Move the tool slowly until it touches (scratches)
the workpiece surface, or position the measuring
dial correspondingly
Display the preset table: The TNC opens the
preset table and sets the cursor to the active table
row
Select functions for entering the presets: The TNC
displays the available possibilities for entry in the
soft-key row. See the table below for a description
of the entry possibilities
Select the line in the preset table that you want to
change (the line number is the preset number)
If needed, select the column (axis) in the preset
table that you want to change
Use the soft keys to select one of the available
entry possibilities (see the following table)
Soft key
Function
Directly transfer the actual position of the tool (the
measuring dial) as the new preset: This function
only saves the preset in the axis which is currently
highlighted
Assign any value to the actual position of the tool
(the measuring dial): This function only saves the
preset in the axis which is currently highlighted.
Enter the desired value in the pop-up window
Incrementally shift a preset already stored in
the table: This function only saves the preset in
the axis which is currently highlighted. Enter the
desired corrective value with the correct sign in
the pop-up window. If inch display is active: Enter
the value in inches, and the TNC will internally
convert the entered values to mm