beautypg.com

HEIDENHAIN PT 855 for Milling User Manual

Page 96

background image

II - 3 Encoders and Measured Value Display

94

Technical Information

POSITIP 855

Setting the display step with linear encoders

With linear encoders, the display step depends on the

• signal period of the encoder (P31.*) and the

• linear subdivision (P32.*).
Both parameters are entered separately for each axis. The linear

subdivision can range from 0.1 to 128 depending on the signal

period of your encoder.
For linear measurement using nut/ballscrew arrangements and

rotary encoders, calculate the signal period as follows:

Signal period [µm] = Drivescrew pitch [mm] · 1000

Line count

Display step, signal period and linear subdivision for linear encoders

Signal period [µm]

2

4

10

20

40 100 200 12 800

Display step

[mm]

[inch]

Linear subdivision

0.000 02

0.000 001 100

–

–

–

–

–

–

–

0.000 05

0.000 002

40

80

–

–

–

–

–

–

0.000 1

0.000 005

20

40 100

–

–

–

–

–

0.000 2

0.000 01

10

20

50 100

–

–

–

–

0.000 5

0.000 02

4

8

20

40

80

–

–

–

0.001

0.000 05

2

4

10

20

40 100

–

–

0.002

0.000 1

1

2

5

10

20

50 100

–

0.005

0.000 2

0.4

0.8

2

4

8

20

40

–

0.01

0.000 5

0.2

0.4

1

2

4

10

20

–

0.02

0.001

–

–

0.5

1

2

5

10

–

0.05

0.002

–

–

0.2

0.4

0.8

2

4

–

0.1

0.005

–

–

0.1

0.2

0.4

1

2

128

0.2

0.01

–

–

–

–

–

–

–

64