background image

II - 5 Measured Value Output

POSITIP 855

Technical Information

105

1

2

3

5

4

1

2

3

5

4

1

2

3

5

4

Examples of character output at the data interface

In all three examples on this page, measured value output is started

with Ctrl B or a switching signal at the EXT input.

The numbers stand for:

1

Coordinate axis

2

Equal sign

3

+/– sign

4

Carriage return

5

Blank line (Line Feed)

Example 1: Linear axis with radius display X = + 5841.2907 mm

X = + 5 8 4 1 . 2 9 0 7

R

2 to 7 places

Decimal point

1 to 6 places

Unit: blank space for mm, " for inches

Actual value display:

R for radius, D for diameter

Distance-to-go display:

r for radius, d for diameter

Example 2: Rotary axis with degrees decimal display C = + 1260.0000°

C = + 1 2 6 0 . 0 0 0 0

W

4 to 8 places

Decimal point

0 to 4 places

Blank space

W for angle (in distance-to-go display: w)

Example 3: Rotary axis with degrees/minutes/seconds display

C = + 360° 23' 45''

C = + 3 6 0 : 2 3 : 4 5

W

3 to 8 places degrees

Colon

0 to 2 places minutes

Colon

0 to 2 places seconds

Blank space

W for angle (in distance-to-go display: w)