beautypg.com

HEIDENHAIN PT 855 for Milling User Manual

Page 89

background image

II - 2 Operating Parameters

POSITIP 855

Technical Information

87

Transferring operating parameters over the data interface

You can archive the operating parameters on the FE 401 B Floppy

Disk Unit or a PC and read them into the POSITIP again whenever

required. For further information on the data interface and data

transfer, see chapter II - 4.

Preparation

ä Access the operating parameters as described above.

ä Go to the second soft-key level.
To read out parameters

ä Enter the program number under which you wish to save the

operating parameters.

ä Press the

Param. Output

soft key

.

POSITIP reads out all operating parameters.

To download parameters

ä Enter the program number under which the operating

parameters are stored on the diskette.

ä Press the

Param. Input

soft key

.

POSITIP replaces all operating parameter settings in its

memory with those on the diskette.

Fig. 39: The POSITIP screen for transfer of

operating parameters