beautypg.com

HEIDENHAIN PT 855 for Milling User Manual

Page 91

background image

II - 2 Operating Parameters

POSITIP 855

Technical Information

89

List of operating parameters

Parameter

Page

Function and

Numerical

allowed entries

entry

*)

P1

mm/inch

97

Dimensions in millimeters: mm 0

P1 ...............

Dimensions in inches: inch

1

P3.1 Radius/Diameter 1

97

Radius display

0

P3.1 ............

P3.2 Radius/Diameter 2

Diameter display

1

P3.2 ............

P3.3 Radius/Diameter 3

P3.3 ............

P3.4 Radius/Diameter 4

P3.4 ............

P6

Axis combination

97

No axis combination: off

0

P6 ...............

1+4 displayed on 1

1

...................

2+4 displayed on 2

2

...................

3+4 displayed on 3

3

...................

1–4 displayed on 1

4

...................

2–4 displayed on 2

5

...................

3–4 displayed on 3

6

P8

Angle format

97

Decimal display: Degrees

0

P8 ...............

Degrees/Minutes/Seconds

1

P9.1 Angle counting 1

97

360°

0

P9.1 ............

P9.2 Angle counting 2

+/– 180°

1

P9.2 ............

P9.3 Angle counting 3

+/– ¥°

2

P9.3 ............

P9.4 Angle counting 4

P9.4 ............

P11

Scaling factor on

79

Scaling factor inactive: off

0

P11 .............

Scaling factor active: on

1

P12.1 Scaling factor 1

79

Scaling factor

P12.1 ..........

P12.2 Scaling factor 2

0.1 bis 9.999 99

1.0

P12.2 ..........

P12.3 Scaling factor 3

P12.3 ..........

P12.4 Scaling factor 4

P12.4 ..........

P23

Display freeze

104

Ignore signal: off

0

P23 .............

Influence position display by

Stop display: concrnt.

1

signal for measured-value output

Freeze display: frozen

2

P25

Stylus diameter

–

0.001 to 999.999 [mm]

6.0

P25 .............

P26

Stylus length

–

–999.999 to 999.999 [mm]

0.0

P26 .............

P30.1 Counting direction 1

93

Positive counting direction

0

P30.1 ..........

P30.2 Counting direction 2

with positive traverse direction

P30.2 ..........

P30.3 Counting direction 3

Negative counting direction

1

P30.3 ..........

P30.4 Counting direction 4

with positive traverse direction

P30.4 ..........

P31.1 Signal period 1

94

Signal period of linear encoder

20

P31.1 ..........

P31.2 Signal period 2

95

(see Operating Instructions

P31.2 ..........

P31.3 Signal period 3

for encoder)

P31.3 ..........

P31.4 Signal period 4

P31.4 ..........

P32.1 Linear subdivision 1

94

Linear subdivision of

20

P32.1 ..........

P32.2 Linear subdivision 2

95

encoder signals

P32.2 ..........

P32.3 Linear subdivision 3

P32.3 ..........

P32.4 Linear subdivision 4

P32.4 ..........

*)

Standard factory settings are in bold italic type