HEIDENHAIN PT 855 for Milling User Manual
Page 106

II - 5 Measured Value Output
104
Technical Information
POSITIP 855
Starting measured value output
Starting measured value output with an edge finder
During the probing functions Edge, Centerline and Circle
Center it is possible to output measured values over the data
interface when the edge finder sends a signal.
The following data are output:
The coordinates of the edge, centerline or circle center
The distance between the two edges (with Centerline)
or the circle diameter (with Circle Center).
Measured value output with the edge finder: P 96
No measured value output during probing:
P96 = 0
Measured values are output during probing:
P96 = 1
Operating parameters for measured value output
The following operating parameters will influence measured value
output regardless of how measured value output is started.
Number of blank lines after each measured value: P51
Number of blank lines (line feeds) after
each measured value:
P51 = 0 to 99
The signal for measured value output can also influence the postion
display on the screen:
Screen display during measured value output: P23
The display is not stopped during measured
value output (Off):
P23 = 0
The display is stopped during measured value
output and remains stopped while the switching
input "output measured value" is active (Concrnt): P23 = 1
The display is stopped but is updated by every
measured value output (Frozen): P23 = 2