II - 5 Measured Value Output

104

Technical Information

POSITIP 855

Starting measured value output

Starting measured value output with an edge finder

During the probing functions Edge, Centerline and Circle

Center it is possible to output measured values over the data

interface when the edge finder sends a signal.
The following data are output:

• The coordinates of the edge, centerline or circle center

• The distance between the two edges (with Centerline)

• or the circle diameter (with Circle Center).

Measured value output with the edge finder: P 96

No measured value output during probing:

P96 = 0

Measured values are output during probing:

P96 = 1

Operating parameters for measured value output

The following operating parameters will influence measured value

output – regardless of how measured value output is started.

Number of blank lines after each measured value: P51

Number of blank lines (line feeds) after

each measured value:

P51 = 0 to 99

The signal for measured value output can also influence the postion

display on the screen:

Screen display during measured value output: P23

The display is not stopped during measured

value output (Off):

P23 = 0

The display is stopped during measured value

output and remains stopped while the switching

input "output measured value" is active (Concrnt): P23 = 1

The display is stopped but is updated by every

measured value output (Frozen): P23 = 2