48
Installing and Connecting the System
Connections between Base Station and Camera Unit
SMPTE Hybrid Fiber between the MPS Power Unit and Camera Unit
Fig. 5-8: SMPTE Hybrid Fiber between the MPS Power Unit and Camera Unit
Between the Base Station (1) and the External Wafer Power Supply (4) connect a pair of ST
Fiber Cables (5). Power the External Wafer Power Supply locally by connecting to AC Power.
Between the External Wafer Power Supply (4) and the Camera Unit connect a length of
SMPTE Hybrid Fiber Cable (3). At each end of the fiber cable will be either an OpticalCON or
SMPTE 304M Connector (7). The Base Station connector (1) may be mounted either on the
front or back of the Base Station. The camera will be powered by the CopperHead Power
Wafer Camera Power Supply (2).The Base Station will be powered by connection to local AC
power (6).
SMPTE Hybrid Fiber between the HDX Power Unit and Camera Unit
Fig. 5-9: SMPTE Hybrid Fiber between the HDX Power Unit and Camera Unit
Between the Base Station (1) and the HDX Power Supply (
4
) connect a pair of ST Fiber
Cables (5). Power the External Wafer Power Supply locally by connecting to AC Power.
Between the External Wafer Power Supply (4) and the Camera Unit connect a length of
SMPTE Hybrid Fiber Cable (3). At each end of the fiber cable must be a SMPTE 304M
Connector (7). The Base Station connector (1) may be mounted either on the front or back
of the Base Station. The camera will be powered by the CopperHead PowerPlus Camera
Power Supply (2). The Base Station will be powered by connection to local AC power (6).