Grass Valley 3404 CopperHead User Manual
Page 37
31
CopperHead 3404
User Guide
• Red when it is not communicating with the Camera Unit
• FIBER LINK - indicates the optical power status of the Base Station and camera
• Green when both the Base Station and camera optical power are within a
normal range.
• Red when both the Base Station and camera optical power are not within a
normal range
• Orange when either the Base Station or camera optical power are not within a
normal range
• ALARM - indicates that some error condition exists in either the Base Station or the
camera.
• Red if there is a Base Station error. Refer to the Base Station DIAG for details on
the error.
• Orange if there is a camera error. Refer to CAM DIAG for details for the error.
• Green when high voltage is being supplied to the camera.
• Off when there is no high voltage applied to the camera
• 15: Hybrid Power Indicators
The Hybrid Power indicators are only applicable to units with the internal power supply
(for configurations using the MPS or HDX power supplies - see
• CAMERA POWER - indicates that high voltage is applied to power the camera
• Green when the cable is properly connected from the Base Station to the
camera.
• Red when there no cable connected to the camera or the cable is connected
but open.
High voltage will not be applied to the camera until the open condition is
corrected.
• CABLE OPEN - indicates that the high voltage cable is open or there is no high
voltage cable connected.
• CABLE SHORT - indicates that the high voltage cable connected is shorted.
• 16: Power Switch & Power Indicator
Toggle switch to enable or disable Base Station power.
LED turns Green when on/off switch is changed to the ON position. With a hybrid
power system (power supplied by the Base Station) this switch will control power to the
Camera and the Camera Unit
For the hybrid system to be properly powered, the AC Mains switch on the rear of Base