Grass Valley 3404 CopperHead User Manual

Page 52

background image

46

Installing and Connecting the System

Connections between Base Station and Camera Unit

The following fiber connection scenarios do not take into account any customized cable
and connector installations you may have at your facility. For assistance regarding more
complex connection situations please contact Grass Valley, a Belden Brand or your local
authorized dealer.

Tactical Fiber between the Base Station and Camera Unit

Fig. 5-5: Tactical Fiber between the Base Station and Camera Unit

Between the Base Station (1) the Camera Unit (2) connect a length of Tactical Fiber Cable
(3). At each end of the fiber cable will be either an OpticalCON or MX Fiber Connector (4)
and (5). The Base Station connector (

4

) may be mounted either on the front or back of the

Base Station. The camera must be powered by local power, either a Battery or a local AC
Power Supply (6).

SMPTE Hybrid Fiber between the Base Station (powered) and Camera Unit

Fig. 5-6: SMPTE Hybrid Fiber between the Base Station (powered) and Camera Unit

Between the Base Station (1) and the Camera Unit (2) connect a length of SMPTE Hybrid
Fiber Cable (3). At each end of the fiber cable will be either an OpticalCON or SMPTE 304M
Connector (4) and (5). The Base Station connector (4) may be mounted either on the front
or back of the Base Station. The camera will be powered by the CopperHead Power Wafer
Camera Power Supply (6).

Note: Your configuration may have the OpticalCON or MX Fiber
Connector (4) directly mounted on the Base Station Chassis or it may
have a panel mounted connector leading to two ST connectors.