Run led fast flashes, Power module failures, Power led is off – H3C Technologies H3C SR6600-X User Manual
Page 87

77
3.
If the LPU is correctly inserted in a slot and the following information is displayed on the serial
terminal and the software management tool, it indicates the power is not sufficient and power
modules need to be added.
%Apr 26 16:46:32:169 2012 H3C DRVMSG/1/InSufficientPwr:
No sufficient power, failed to power on slot 3.
4.
If the usable power is normal, the LPU is faulty. Execute the display version command. The
following output appears.
Slot3:
The Board is present, state is unknown
5.
If the problem persists, contact your local sales agent.
RUN LED fast flashes
20 minutes after the router is powered on or the LPU is inserted into the router, if the RUN LED of the LPU
still fast flashes at 8 Hz, it indicates that the LPU application program fails to start or the LPU is faulty. In
this case, the LPU is in startup state, and if you enter the display device command, the system displays the
following output:
System-mode(Current/After Reboot): Normal/Normal
Slot No. Board type Status Primary SubSlots
--------------------------------------------------------
0 N/A Absent N/A N/A
1 N/A Absent N/A N/A
2 N/A Absent N/A N/A
3 FIP-210 Normal N/A 2
4 RSE-X2 Normal Master 0
5 N/A Absent N/A N/A
6 N/A Absent N/A N/A
7 N/A Absent N/A N/A
8 FIP-210 Startup N/A 2
9 FIP-600 Startup N/A 2
The output shows that LPUs in Slots 8 and 9 have failed.
To solve this problem, contact your local sales agent.
Power module failures
Power LED is off
If the router cannot be powered on and the power LED on the front panel is off, it indicates that the power
module is faulty.
To troubleshoot the power module failure:
1.
Verify that the power switch is turned on.
2.
Verify that the power cords of the router are firmly connected.
3.
Verify that the switch of the power source is turned on.
4.
Verify that the power cord is not damaged.