beautypg.com

Fip-240 combo interface specifications, Fip-300 – H3C Technologies H3C SR6600-X User Manual

Page 117

background image

107

Item Remarks

Memory type and size

Default—One 2-GB DDR3 SDRAM

Maximum—Two 2-GB DDR3 SDRAMs

NVRAM 128

KB

Combo interface

2

2 copper ports (MDI/MDIX
autosensing)

10 Mbps, half/full-duplex

100 Mbps, half/full-duplex

1000 Mbps, full-duplex

2 fiber ports

1000 Mbps, full-duplex

MIM 4

supported

HIM

2 full-height or 4 half-height HIMs supported
(Half-height HIMs include HIM-4G4P, HIM-TS8P, and HIM-8GBP-V2.)

Hardware encryption

Supported

Hot swapping

Supported

NOTE:

For a combo interface, the default operating port is the copper port. You can use either the copper port
or the fiber port. To switch between the copper and fiber ports, use the combo enable { copper | fiber }

command in interface view. For more information about the combo enable { copper | fiber } command,

see

H3C SR6600/SR6600-X Routers Interface Command Reference.

Use transceiver modules for the fiber ports provided by H3C only. The router might be incompatible with
transceiver modules from other manufacturers. The system generates an alarm when a transceiver

module from another manufacturer is installed.

FIP-240 combo interface specifications

Specification of combo interfaces on the FIP-240 and the FIP-110 are the same. For more information,

see

Table 33

and

Table 34

.

Transceiver modules available for the FIP-240 fiber ports are the same. For more information, see

Table

35

.

Maximum interface modules provided by FIP-240 in full configuration

FIP/Interface module SR6604-X

SR6608-X

SR6616-X

FIP-240 2

4

8

MIM 8

16 32

HIM

4 (8 half-height HIMs)

8 (16 half-height HIMs)

16 (32 half-height HIMs)

FIP-300

The FIP-300 supports HIMs and MIMs, and it provides 12 combo interfaces.