Troubleshooting, Mpu failures, Run led is off – H3C Technologies H3C SR6600-X User Manual

Page 85: Run led fast flashes, Alm led is steady on or flashes

background image

75

Troubleshooting

IMPORTANT:

The barcode stuck on the router chassis contains production and servicing information. Before you return
a faulty router for serving, provide the barcode information of the router to your local sales agent.

MPU failures

RUN LED is off

When the RUN LED of the MPU is off, it indicates that the MPU is powered off or faulty. For more

information about the RUN LED, see

Table 19

.

To troubleshoot the MPU failure:

1.

Verify that the MPU is plugged in a right slot.

2.

Verify that the router is powered on normally. A green power LED indicates that the router is
powered on normally.

3.

If the cause cannot be located in the steps above and the problem persists, contact your local sales
agent.

RUN LED fast flashes

Five minutes after the router is powered on or the MPU is plugged into the router, if the RUN LED of the

MPU still fast flashes at 8 Hz, it indicates that the MPU application program fails to start or the MPU is
faulty.
To troubleshoot the MPU failure:

1.

Verify that the terminal display is correct.

2.

Verify that the application program file properties are correct in the BootWare menu.

3.

If the cause cannot be located in the steps above and the problem persists, contact your local sales
agent.

ALM LED is steady on or flashes

If the ALM LED of the MPU is steady on or flashes, it indicates that the router is faulty. For example, the

ALM LED is on when the system is over-temperature.
To solve the problem, examine the output (such as alarms on the system temperature, power voltage or
insufficient power for use) on the serial terminal and the software management tool.
If the cause cannot be located and the problem persists, record the above information, and contact your

local sales agent.