beautypg.com

Power consumption – H3C Technologies H3C SR6600-X User Manual

Page 103

background image

93

Model Net

weight Dimensions (H × W × D)

FIP-110

3.25 kg (7.16 lb)

45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)

FIP-210

3.35 kg (7.39 lb)

45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)

FIP-240

3.45 kg (7.61 lb)

45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)

FIP-300

3.65 kg (8.047 lb)

45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)

FIP-310

3.65 kg (8.047 lb)

45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)

FIP-600

3.55 kg (7.83 lb)

45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)

SAP-48GBE

3.8 kg (8.38 lb)

45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)

SAP-24GBP

3.3 kg (7.28 lb)

45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)

SAP-48GBP

3.7 kg (8.16 lb)

45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)

SAP-4EXP

3.7 kg (8.16 lb)

45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)

Power consumption

Table 22 Card power consumption

Model Actual

power consumption

Theoretical power consumption

RSE-X2

46 W

75 W

SFE-X1

67 W

100 W

FIP-110

60 W

75 W

FIP-210

110 W

125 W

FIP-240

156 W

200 W

FIP-300

132 W

150 W

FIP-310

128 W

150 W

FIP-600

114 W

150 W

SAP-48GBE

162 W

200 W

SAP-24GBP

125 W

150 W

SAP-48GBP

132 W

200 W

SAP-4EXP

109 W

150 W

NOTE:

The theoretical power consumption, greater than the actual power consumption, is the upper power
consumption threshold defined to avoid power module overloading. You must use the theoretical power

consumption, rather than the actual power consumption, to calculate the total power consumption for
managing power modules and determining power module numbers.

Table 23 Fan power consumption

Model Power

consumption

RT-FAN-6604-X 82

W