93
Model Net
weight Dimensions (H × W × D)
FIP-110
3.25 kg (7.16 lb)
45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)
FIP-210
3.35 kg (7.39 lb)
45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)
FIP-240
3.45 kg (7.61 lb)
45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)
FIP-300
3.65 kg (8.047 lb)
45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)
FIP-310
3.65 kg (8.047 lb)
45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)
FIP-600
3.55 kg (7.83 lb)
45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)
SAP-48GBE
3.8 kg (8.38 lb)
45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)
SAP-24GBP
3.3 kg (7.28 lb)
45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)
SAP-48GBP
3.7 kg (8.16 lb)
45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)
SAP-4EXP
3.7 kg (8.16 lb)
45 × 399 × 412 mm (1.77 × 15.71 × 16.22 in)
Power consumption
Table 22 Card power consumption
Model Actual
power consumption
Theoretical power consumption
RSE-X2
46 W
75 W
SFE-X1
67 W
100 W
FIP-110
60 W
75 W
FIP-210
110 W
125 W
FIP-240
156 W
200 W
FIP-300
132 W
150 W
FIP-310
128 W
150 W
FIP-600
114 W
150 W
SAP-48GBE
162 W
200 W
SAP-24GBP
125 W
150 W
SAP-48GBP
132 W
200 W
SAP-4EXP
109 W
150 W
NOTE:
The theoretical power consumption, greater than the actual power consumption, is the upper power
consumption threshold defined to avoid power module overloading. You must use the theoretical power
consumption, rather than the actual power consumption, to calculate the total power consumption for
managing power modules and determining power module numbers.
Table 23 Fan power consumption
Model Power
consumption
RT-FAN-6604-X 82
W