Numbering interfaces, Examples, Example 1 – H3C Technologies H3C SR6600-X User Manual
Page 143: Fixed gigabitethernet interfaces on the fip-110, Gigabitethernet interfaces on the mim-2gbe

133
Card SR6604-X
SR6608-X
SR6616-X
FIP-110/210/240/30
0/310/600
SAP/OAP card
Slot 2 and Slot 3
Slot 2 through Slot 5
Slot 0 through Slot 3, and
Slot 6 through Slot 9
Numbering interfaces
Before installing a HIM/MIM, you must install a FIP. A FIP-210/FIP-240/FIP-300/FIP-310 supports both
HIMs and MIMs, while a FIP-110 supports only MIMs, and a FIP-600 supports only HIMs.
The interfaces of the router are numbered in the form of interface-type X/Y/Z,
Where,
•
interface-type—Type of the interface such as GE port and serial port.
•
X—Number of the slot where the FIP/SAP resides (for example, blue numbers in
through
).
Different HIMs/MIMs on the same FIP have the same slot number X.
•
Y—Sub-slot number, the number of the slot where the HIM/MIM resides on the FIP. If a SAP/OAP
is installed, the sub-slot number is 0.
Different interfaces on the same HIM/MIM have the same sub-slot number Y.
•
Z—Sequence number of the interface on the HIM/MIM or on the SAP/OAP.
For each type of interface, the sequence number Z starts from 0 on the HIM/MIM.
Examples
Example 1
A MIM-2GBE module is installed on the FIP-110 in slot 3.
Fixed GigabitEthernet interfaces on the FIP-110
•
GigabitEthernet 3/0/0
•
GigabitEthernet 3/0/1
NOTE:
The sub-slot number Y of fixed GE interfaces on a FIP is 0.
GigabitEthernet interfaces on the MIM-2GBE
1.
If the MIM-2GBE is installed in slot 1 of the FIP-110, the GigabitEthernet interfaces are:
{
GigabitEthernet 3/1/0
{
GigabitEthernet 3/1/1
2.
If the MIM-2GBE is installed in slot 2 of the FIP-110, the GigabitEthernet interfaces are:
{
GigabitEthernet 3/2/0
{
GigabitEthernet 3/2/1