Displaying the electrical label data – H3C Technologies H3C SR6600-X User Manual
Page 76

66
Subslot 2 : MIM-2GBE
•
Use the display device slot slot-number command to display detailed information about the card in
the specified slot.
System-mode(Current/After Reboot): Normal/Normal
Slot 1 : RSE-X2
SubSlot No. Card Type Status Max Ports
--------------------------------------------------------
1 Fixed SubCard Normal 3
Table 10 Command output
Field Description
Slot No.
Slot number of the card.
Card Type
Card model. The value NONE indicates that no card is present in the slot.
Status
Running status of the card:
•
Absent—No card is present in the slot.
•
Fault—The card in the slot is booting, or the card has failed and cannot boot
correctly.
•
Normal—The card in the slot is operating correctly.
Max Ports
Maximum number of ports that the card supports.
Displaying the electrical label data
Electrical label data is also called permanent configuration data or archive information, which includes
the card name, serial number, MAC address, and vendor name.
•
Use the display device manuinfo command to display the electrical label data for the card in each
slot.
Slot 0:
DEVICE_NAME: RT-RSE-X2
DEVICE_SERIAL_NUMBER: 210231A1RG0000000002
MAC_ADDRESS: 00FE-1230-1230
MANUFACTURING_DATE: 2011-12-12
VENDOR_NAME:H3C
•
Use the display device manuinfo slot slot-number command to display the electrical label data for
the card in the specified slot.
Slot 0:
DEVICE_NAME: RT-RSE-X2
DEVICE_SERIAL_NUMBER: 210231A1RG0000000002
MAC_ADDRESS: 00FE-1230-1230
MANUFACTURING_DATE: 2011-12-12
VENDOR_NAME:H3C