H3C Technologies H3C SR6600-X User Manual
Page 136

126
LED Status
Description
(yellow/green)
Status LEDs
of SFP 0 to
SFP 23
Off
No link is present.
Steady green
A 1000 Mbps link is present.
Flashing green
Data is being received or transmitted at a rate of 1000
Mbps.
Steady yellow
A 100 Mbps link is present.
Flashing yellow
Data is being received or transmitted at a rate of 100
Mbps.
Figure 116 SAP-48GBP LEDs
Table 48 SAP-48GBP LED description
LED Status
Description
(green)
RUN
Off
No power input is available or the SAP-48GBP has failed.
Slow flashing (1 Hz) The SAP-48GBP is operating correctly.
Fast flashing (8 Hz)
Application program is being loaded or the SAP-48GBP
is not operating.
CAUTION:
To avoid hardware damage, do not power off the router, or
insert or remove the SAP-48GBP when application
program is being loaded.
(yellow/green)
Status
LEDs of
SFP 0 to
SFP 47
Off
No link is present.
Steady green
A 1000 Mbps link is present.
Flashing green
Data is being received or transmitted at a rate of 1000
Mbps.
Steady yellow
A 100 Mbps link is present.
Flashing yellow
Data is being received or transmitted at a rate of 100
Mbps.
Figure 117 SAP-4EXP LEDs