beautypg.com

Figure 78, To remove the filler panel. pu – H3C Technologies H3C S5800 Series Switches User Manual

Page 79

background image

69

Figure 78 Remove the filler panel over the OAP card slot

(1) Rotate counterclockwise

(2) Filler panel over the OAP card slot

(3) Phillips screwdriver

3.

Unpack the OAP card and check that this OAP card can be installed in the OAP card slot.

4.

Hold the OAP card with the ejector levers on top, push the OAP card slowly along the guide rails

into the slot (see callout 3 in

Figure 79

), and push the ejector levers inward to lock the OAP card

in position (see callout 4 in

Figure 79

).

Figure 79 Install an OAP card

(1) OAP card

(2) Chassis rear panel

(3) Push the OAP card

(4) Push the ejector levers inward

CAUTION:

Do not touch the surface-mounted components directly with your hands.

Do not use excessive force while installing the OAP card. If you cannot insert the OAP card smoothly,
check the installation method for mistakes.

5.

Fasten the captive screws on the OAP card with the Philips screwdriver to secure the OAP card in
the slot.

Removing the card in the OAP card slot (only for the

S5800-60C-PWR)

1.

Wear an ESD-preventive wrist strap, ensure a good skin contact and make sure that the

ESD-preventive wrist strap is correctly grounded.

2.

Loosen the captive screws on the OAP card with the Philips screwdriver until all spring pressure is

released.

(1)

(2)

(3)