Interface card status led, Hot swappable power modules – H3C Technologies H3C S5800 Series Switches User Manual
Page 35
25
Table 22 PoE module status LED description
LED mark
Status
Description
SLOT4
Green
The PoE module is in position and operating correctly.
Flashing yellow (1 Hz)
The switch does not support the PoE module model, or the PoE
module has failed.
Off
The PoE module slot is empty.
Interface card status LED
The S5800-56C, S5800-56C-PWR, S5800-32C, and S5800-32C-PWR switches have an interface card
status LED to show the status of the interface card or the OAP card in the expansion interface card slot.
Table 23 Description of the interface card status LED
LED mark
Status
Description
SLOT1
Green
The interface card or the OAP card is in position and operating
correctly.
Flashing yellow (1 Hz)
The slot does not support the card model, or the card has failed.
Off
The expansion interface card slot is empty.
Hot swappable power modules
The S5800-60C-PWR, S5800-54S, and S5800-32F switches have two power module slots. You can
install one power module, or for redundancy, two power modules in
for these switches. All these
power modules are hot swappable. For how to install or remove a power module, see
"
Installing/Removing a power module
Table 24 Power module specifications and the compatibility with the H3C S5800 Switch Series
Power module Specifications
switch chassis
Reference
PSR150-A
PSR150-A1
•
Rated input voltage range:
100 VAC to 240 VAC @ 50 Hz or 60
Hz
•
Max input voltage range:
90 VAC to 264 VAC @ 47 Hz or 63 Hz
•
Max output power:
150 W
S5800-32F
H3C PSR150-A &
PSR150-D Series
Power Modules User
Manual
PSR150-D
PSR150-D1
•
Rated input voltage range:
–48 VDC to –60 VDC
•
Max input voltage range:
–36 VDC to –72 VDC
•
Max output power:
150 W
S5800-32F
H3C PSR150-A &
PSR150-D Series
Power Modules User
Manual