Upgrading software from the cli – H3C Technologies H3C S10500 Series Switches User Manual
Page 12

11
3.
Copy the file newest.bin to the root directory of the storage medium on each standby MPU of the
IRF fabric.
•
On the standby MPU in slot 1 of member device 1
Copy flash:/newest.bin to chassis1#slot1#flash:/newest.bin?[Y/N]:y
%Copy file flash:/newest.bin to chassis1#slot1#flash:/newest.bin...Done.
•
On the standby MPU in slot 0 of member device 2
Copy flash:/newest.bin to chassis2#slot0#flash:/newest.bin?[Y/N]:y
%Copy file flash:/newest.bin to chassis2#slot0#flash:/newest.bin...Done.
•
On the standby MPU in slot 1 of member device 2
Copy flash:/newest.bin to chassis2#slot1#flash:/newest.bin?[Y/N]:y
%Copy file flash:/newest.bin to chassis2#slot1#flash:/newest.bin...Done.
NOTE:
You can configure the switch as the FTP server, FTP client, or TFTP client. The transfer processes slightly
vary. For more information about FTP and TFTP, see the
Fundamentals Configuration Guide in the H3C
S10500 Switch Series Configuration Guides.
Upgrading software from the CLI
NOTE:
Make sure that all the files used for upgrade exit in the root directory of the storage medium of the active
and standby MPUs of the IRF fabric.
Perform the following tasks as needed:
•
•
•
1.
Upgrade BootWare
The following example uses mpu.btw, lpu.btw, and lpo.btw files to upgrade the BootWare of MPUs, LPUs,
switching fabric modules respectively.
NOTE:
The BootWare image stored on the active MPU can be used to upgrade the active MPU, LPUs, and
switching fabric modules while that stored on a standby MPU is used to upgrade the standby MPU only.
# Upgrade the BootWare for the active MPU.
This command will update bootrom file on the specified board(s),
Continue? [Y/N]:y
Now updating bootrom, please wait...
Start accessing bootflash chip...
Bootrom update succeeded in chassis 1 slot 0.