beautypg.com

5 restoring the controller to factory defaults, 6 verifying software checksums – AEC VacTrac Series Conveying Systems User Manual

Page 76

background image

VacTrac™ Conveying Systems

12-Station Controllers

Page 75

ROM CHECKSUM: 0x0000

PRESS YES TO RESUME

8-5 Restoring the Controller to Factory Defaults

Although rare, you may experience a condition when you need to
perform a total reset of the controller. To do so, perform the
following procedure.

Note: All parameters you set are lost when doing this

procedure, including passwords and OEM Service settings.

Follow these steps to restore the controller to factory defaults.

1.

Remove power from the controller.

2.

Press and hold the

CLEAR

key.

3.

Re-apply power while holding down the

CLEAR

key.

During initialization, the screen displays a message
indicating that factory default settings are set.

8-6 Verifying Software Checksums

Follow these steps to verify software checksum values.

1.

Remove power from the controller.

2.

Press and hold the

SET

key.

3.

Re-apply power while holding down the

SET

key.

During initialization, the screen displays a message while
the controller calculates the software check sum. This
number is in hexadecimal format (Base 16) and displays in
numbers and letters.

Example:

0x1FC9

is a valid checksum format.