CHAPTER 5 SENSOR SETTINGS

Figure 5.2 – General Tab

˽

Serial Number – Contains the sensor serial number and can only be edited if you are

in the Advanced Sensor Setup mode (conatct Wavetronix Technical Services for more

information).

˽

Sensor ID – Allows you to enter a multi-drop address for the sensor. The ID default

is the last four digits of the sensor serial number. The sensor ID can be changed, but

no two sensors should have the same ID; the ID must be unique for all sensors on a

multi-drop bus.

˽

Description – Allows you to enter a description for each sensor (i.e. its function, ap-

plication or intended use). Limited to 32 characters.

˽

Location – Allows you to enter the location of the sensor or the approach. Limited to

32 characters.

˽

RF Channel – Displays which radio frequency channel (or non-interference channel)

the device is transmitting on. Using multiple SmartSensor Advance devices in close

proximity will require each one to be set to a different RF channel. Similarly, using

multiple SmartSensor Advance Extended Range devices in close proximity will require

each one to be set to a different RF channel. However, a SmartSensor Advance device

will not interfere with a SmartSensor Advance Extended Range device, even if they

are on the same RF channel. This is because the hardware used to transmit the Digital

Wave Radar signal is configured differently on the different devices.

Note

It is recommended that the sensor's detection sensitivity be reconfigured after
changing from one RF channel to another.