CHAPTER 8 VERIFY CHANNELS-ALERTS-ZONES

Dynamic Density

The Dynamic Density parameters determine the number of trackers that are required to

meet the specified level of efficiency.

Figure 8.15 describes the text displayed when the Qualified Count is lower than, equal to,

or higher than the Dynamic Density thresholds. The number of qualified detections is fol-

lowed by a percentage number. The percentage is the count ratio of the current number of

qualified detections divided by the DDCR (see Figure 8.16).

Detected

Qualified Count

Dynamic Density

Threshold

Displayed Text

2

4

02 (050%)

4

4

04 (100%)

6

4

06 (150%)

Figure 8.15 – Display Text for Dynamic Density Zone Types

(DDCR)

Percentage

=

Number of Qualified Detections

x 100%

Figure 8.16 – Percentage Equation

The zone output will be activated when the count ratio is equal to or greater than 100 per-

cent. The percentage is displayed in the roadway display to help you tune the Dynamic

Density parameters and extend the green light when desired.

Note

It is recommended that you adjust the Tuning Factor instead of the Headway and
%Utilization parameters.