CHAPTER 12 • PROGRAMMING CONTACT CLOSURES

131

Note

A Click 100 16-output contact closure module can be used if the cabinet you are con-
necting to does not have an input file rack.

Select button

Settings switch

Display

Channel button

Channel LEDs

RS-485 ports

Figure 12.2 – Click 172/174 Cards

To program the Click 172/174 contact closure cards:
1 Plug the surge card into the input file rack. Make sure the Settings switch is in the 3

position when plugged in. Wait approximately 20 seconds.

2 Move the Settings switch to the 1 position and after the auto-baud is complete, the cur-

rent mode will appear.

3 Toggle the Select button to select AC or Actuation mode.

4 Move the Settings switch to the 2 position and wait a few seconds.

5 Move the Settings switch to the 3 position.

6 Wait approximately 30 seconds and then confirm that the detections are registering on

the Channel LEDs.

In many cases, you can put multiple alerts on each channel to avoid the need for more than