As an alternative to collecting a log file with tracker data, you can also log the pulse totals to
a tracker log file. To do so you must select a tracker log file name that ends with the string
“_Pulse.txt” as shown in Figure 8.23.
Figure 8.23 – Select Pulse Log File
Note
If you would like to collect tracker data with pulse total data interspersed, select a
tracker log file name that ends with the string “_TrackerAndPulse.txt”. An asterisk is
placed at the beginning of each pulse total line to help in parsing.
After selecting a file, click the ON/OFF toggle switch icon on the Verify Channels-Alerts-
Zones screen to the ON position to begin tracker logging. Once activated, the duration of
the logging session is displayed on the Elapsed: timer display. Click the toggle switch to the
OFF position to end a tracker logging session.
The tracker log file is an ASCII text file and can be viewed using a standard text editor. Click
on the View Log icon to view the current log file using the system’s default text editor (see
Figure 8.24).