Verilink T1 Access Router (34-00327) Product Manual User Manual
Page 63

W e b S e r v e r I n t e r f a c e
3-35
remote unit answers to the discovery frames sent by this unit. The status is
“SOS” if the remote unit is active but the FRAD/Router connected to it is
inactive. The status is “Inactive” in all other cases.
Values: Active, Inactive, SOS
Default: Inactive
Remote DLCI
If the remote unit is a Verilink FSx product, and FrameStart Auto Discovery
is enabled, this displays the DLCI number used on the remote end of this
DLCI.
Values: 16
−
1023
Default: 0
Remote Unit
If the remote unit is a Verilink FSx product, and FrameStart Auto Discovery
is enabled, this parameter gives the first three digits of the unit ID configured
on the remote end of this DLCI.
Values: 000
−
999
Default: 000
Remote Unit IP
Address
Displays the IP address of the remote Verilink unit with FrameStart
technology if FrameStart Auto Discovery is enabled.
Round Trip Delay Size
(bytes)
Specifies the frame size (in bytes) of packets making the round-trip. If the
Round Trip Delay Size is not configured, the Frame Relay Details values will
be used.
Round Trip Delay Rate
(secs)
Specifies the rate (in seconds) at which Round Trip Delay packets are sent. If
the Round Trip Delay Rate is not configured, the Frame Relay Details values
will be used.
DLCI Status Table
The bottom portion of the screen displays a table detailing the actual status of
DLCI and alarm threshold information as follows:
Status
If this DLCI is up, the status will be “Active”; otherwise, the status will be
“Inactive.”
Values: Active, Inactive
Default: Inactive
Receiving FECN/
BECN
When a frame is received with congestion bit set, this parameter is set to
“Yes.” It is set back to “No” when a frame is received without congestion bit
set.
Values: Yes, No
Default: No
CIR Threshold
Sets the Tx over CIR alarm threshold. This threshold is the number of bits per
second in excess of CIR during a 15-minute interval. Setting this field to “0”
(zero) disables the alarm.