Configuring the DPRI 2922 Via the NCM 2000 Craft Interface
Verilink DPRI 2922
3-15
Data Port
Configuration
Menu
To access the Data Port Configuration Menu, enter D from the
Configuration Menu, Figure 3-3.
Figure 3-8 Data Port Configuration Menu
Table 3-9
Data Port Configuration Menu Commands
Command
Description
Options
In
In Service: Use this option to place the port in service.
Yes or No
(Y/N)
Mn
Data Port Mode: Use this option to select one of the following:
Data Terminal Equipment (DTE): if the equipment connected to the DPRI is a
DCE, then the Data Port Mode is DTE.
Data Circuit-terminating Equipment (DCE): if the equipment connected to the
DPRI is a DTE, then the Data Port Mode is DCE. DCE is the default setting.
1) DTE
2) DCE
[0.0.0.5] [1,2] DPRI 2922 > d
-- DPRI 2922 DATA PORT CONFIGURATION MENU --
PORT 1 PORT 2
In) In Service NO NO
Mn) Data Port Mode DCE DCE
Cn) Clock Option ST ST
Ln) Control Line Indicator LOW LOW
SRn) DSR/LOW DSR/LOW
SSn) CTS/LOW CTS/LOW
SDn) DCD/LOW DCD/LOW
SMn) TM /LOW TM /LOW
DTR/LOW DTR/LOW
RTS/LOW RTS/LOW
LLB/LOW LLB/LOW
RLB/LOW RLB/LOW
DPL Loopback DISABLE DISABLE
Test Pattern NONE NONE
Test Error Counter 0 0
X) exit this screen
[0.0.0.5] [1,2] DPRI 2922 >
Port
Status