Quick Set-Up

2-2

Verilink DPRI 2922

Bus

Compatibility

If there is no indication of the DIDCSU on the “shelf map” on the
NCM Main Menu, the modules may be assigned to different busses
on the shelf backplane.

NCMs are usually sent out with their default bus being the C bus.
Other modules usually are sent out with their default bus being the
A bus.

Assign the DIDCSU to the bus on which the NCM resides by
accessing the DIDCSU’s ASCII port directly.

1. Connect the Craft Interface Cable directly to the LOCAL port

on the DIDCSU module.

2. At the prompt, type craft, then press E

NTER

.

3. At the

PASSWORD:

PASSWORD:

PASSWORD:

PASSWORD: prompt, type “verilink”.

4. From the DIDCSU Main Menu, select the following:

ACE Controller Menu>
O) ACE Controller Administration Menu>
B) Change the ACP Bus

5. Once the bus assignment has been made, reboot the

reassigned module by either

Using the

Reboot

Reboot

Reboot

Reboot command from the ACE Controller

Administration Menu, option R, or

Reseating the module in its slot.

Reconnect to the NCM Local port for further operations.