Quick set-up, Getting started, Terminal parameters – Verilink DPRI 2922 (880-503142-001) Product Manual User Manual
Page 17: Logging on, Quick set-up -1, Getting started -3, Terminal parameters -3 logging on -3, Chapter

Verilink DPRI 2922
2-1
Chapter
2
Quick Set-Up
This chapter provides step-by-step procedures as an example for
setting up your DIDCSU 2912 module.
NOTE: Since the following procedures may not exactly apply to your
specific application, use them only as as a guide for the
configuration process. Complete descriptions of the various screen
options and suggestions for their applicability to your situation are
given in the following chapter.
NOTE: For the most effective and efficient set-up, have all required
planning data such as your intended use, network (telco) provider
specifications, channel and line requirements, circuit
configurations, and other important information handy. For your
convenience, worksheets are provided in the AS2000 Basics Manual,
Chapter 2—Site Planning.
Getting Started
After the NCM and DIDCSU modules and their NIM/CIM have been
installed in their appropriate shelf/slots (self-test has been
successfully completed), connect the Craft Interface Cable
(P/N 458-501788-008) to the Local port on the NCM front panel to
access the ASCII interface.
Terminal
Parameters
Terminal parameters: 19.2 kbit/s baud rate, 8 data bits, no parity,
one stop-bit, and no flow-control. Make sure that the X-On/X-Off
flow control is disabled.
Logging On
1. Press E
NTER
to display the pSH+> prompt and type craft.
2. Press E
NTER
to display the NCM Main Menu.
If the NCM Main Menu display
proper shelf/slot position, you may continue with the
configuration tasks.
The default password for the NCM will give the user Access Level 2
permissions. If you need a higher access level, see your NCM 2000
User Manual for more information.