Quick Set-Up

2-10

Verilink DPRI 2922

2. Set the Switch Type, Own Numbering Plan, and Own

Numbering Type according to the parameters your NSP has
provided you (use the checksheet provided). The choices
shown above are a possible (and recommended) configuration.

3. Set the Security Level according to your particular needs.

4. Set the L2 auto establish to “Yes”. It allows for verification of

signal connection.

Setting Alarm (Backup Trigger) Parameters

When normal T1 service is interrupted, errored, or lost, an alarm
triggers the backup circuit. Therefore, this alarm must be set for
the T1/Data Ports you want to monitor/trigger for backup
activation.

1. Select A from the Main Menu, Figure 2-1, to access the Net

Port Alarm Menu.

2. Set the “Card Alarm Reporting” option (A) to

YES

.

Figure 2-9 Net Port Alarm Menu

3. Select C to configure thresholds.

A [127.255.255.0] [1,2] DIDCSU 2912 > a

-- DIDCSU 2912 NET PORT ALARM MENU --

N) NMS Address 128.0.0.0

A) Card Alarm Reporting YES

C) Configure Thresholds S) Alarm status

O) Display Alarm Buffer Tn) Set Default Thresholds

X) exit this screen

A [127.255.255.0] [1,2] DIDCSU 2912 >