Configuration menu, Configuration menu -6, Table 3-3 – Verilink DPRI 2922 (880-503142-001) Product Manual User Manual
Page 36: Figure 3-3, Table 3-4

Configuring the DPRI 2922 Via the NCM 2000 Craft Interface
3-6
Verilink DPRI 2922
Table 3-3
Card Administration Submenu Commands
Configuration Menu
Typing the command
C
from Main Menu displays the DPRI 2922
Configuration Menu. This menu provides access to the menus
used to configure the T1 port, data port, or ISDN PRI options.
Figure 3-3 Configuration Menu
Table 3-4
Configuration Menu Commands
Command
Description
Options
O
Switch over permanent—This option designates the partition A or B firmware
version when you reboot the card. Assign a permanent partition to boot from
in case of power failure. Before choosing a partition, ensure that a firmware
version exists on both partitions using the Query Firmware command below.
1) A
2) B
Q
Query Firmware—Use this option to display the firmware versions and their
status for the A and B flashbanks (unless a flashbank is empty).
R
Reset Card—This option reboots the module.
Y
Switch Over Once—Use this option when testing new firmware versions to
change from partition A to B or vice versa. The next time you reboot, the
module will use the original partition/flashbank. Though you can use this
option for diagnostics, you should nevertheless indicate a permanent partition
to boot from in case of power failure.
1) A
2) B
I
Change Site Name—Use this option to specify the site name for the DPRI.
Limited to 19 viewable characters. All reports will contain this information
which—in case of a problem—will help to identify the module location.
U
Clear Card Configuration—This option clears the configuration of the card and
returns it to the default settings. NOTE: Use with Caution!
[0.0.0.5] [1,2] DPRI 2922 > u
[0.0.0.5] [1,2] DPRI 2922 > u
[0.0.0.5] [1,2] DPRI 2922 > u
[0.0.0.5] [1,2] DPRI 2922 > u
Clear card configuration on shelf 1 slot 2 (Y/N)? y
Clear card configuration on shelf 1 slot 2 (Y/N)? y
Clear card configuration on shelf 1 slot 2 (Y/N)? y
Clear card configuration on shelf 1 slot 2 (Y/N)? y
Card configuration cleared
Card configuration cleared
Card configuration cleared
Card configuration cleared
Yes or No
(Y/N)
X
Exit this Screen—Returns you to the Main Menu, Table 3-1.
Command
Description
P
T1 port—Displays the DPRI 2922 T1 Port Configuration Menu, Figure 3-4, Table 3-5.
D
Data port—Displays the Data Port Configuration Menu, Figure 3-8, Table 3-9.
I
ISDN PRI—Displays the PRI Configuration Menu, Figure 3-10, Table 3-10.
X
Exit this Screen—Returns you to the Main Menu, Table 3-1, Table 3-2.
[0.0.0.5] [1,2] DPRI 2922 > c
-- DPRI 2922 CONFIGURATION MENU --
P) T1 port D) data port
I) ISDN PRI X) exit this screen
[0.0.0.5] [1,2] DPRI 2922 >