SurvCE™ Integration User Guide – Rev. A

3-62

from Base Configuration, From Known
Position (see Figure 82).

1. Enter the number of autonomous navigation

solutions to be averaged at the base receiver.

It is extremely important to have an
accurate base position. Any error in the
input base coordinate will directly bias
the rover positioning accuracy.

2. Tap

to accept the settings. An average of

the number of positions is taken. The Base
Configuration window opens to display the
position (see Figure 31).

Figure 31: Base Configuration Window

Note the version updates.

Broadcast ID box added.

3. Tap the Yes button to continue with the base

setup. Tap the No button to return to the