beautypg.com

Settings/security settings – Grandstream GVC3200 Administration Guide User Manual

Page 48

background image

Firmware Version 1.0.1.5

GVC3200 Administration Guide

Page 47 of 61

Disable Remote
Control App
Connect

If set to “Yes”, the Remote Control app can be paired to the GVC3200 via Bluetooth,
but it cannot connect to the GVC3200 to perform any operations. The default setting
is “No”.

Remote Control
Touchpad
Sensitivity

Configure the sensitivity of the remote control trackpad. Users can select Slow,
Normal or Fast. The default setting is Normal.

Keep-alive Interval
(s)

It is used to specify how often the GVC3200 system will send a Binding Request
packet to the SIP server in order to keep the "ping hole" on the NAT router to open.
The default setting is 20 seconds. The valid range is from 10 to 160.

STUN Server

It is used to configure the URI of STUN (Simple Traversal of UDP for NAT) server.
The GVC3200 system will send STUN Binding Request packet to the STUN server
to learn the public IP address of its network. Only non-symmetric NAT routers work
with STUN. The default setting is "stun.ipvideotalk.com".

TURN Server
Username

It is used to configure the username for TURN server.

TURN Server
Password

It is used to configure the password for TURN server.

Use NAT IP

It is used to configure the IP address for the Contact header and Connection
Information in the SIP/SDP message. It should ONLY be used if it's required by your
ITSP. The default setting is keep the box blank.

SETTINGS/SECURITY SETTINGS

Parameters

Descriptions

Web/SSH Access

Disable SSH

It is used to set if the GVC3200 system will block the SSH port.
If it is set to "Yes", the GVC3200 system will block any SSH access to the phone.
The default setting is "No".

Access Method

It is used to set which protocol will be used to access the phone‘s Web GUI. It can
be selected from HTTP and HTTPS. The default setting is HTTP.

Port

It is used to set which port will be used to access the phone‘s Web GUI. By default, if
HTTP is selected, the port number will be 80; if HTTPS is selected, the port number
will be 443.

Admin Password

It is used to set the administrator password for Web GUI. It is case sensitive with a
maximum length of 32 characters. The default password is "admin".

User Password

It is used to set the user password for Web GUI. It is case sensitive with a maximum
length of 32 characters. The default password is "123".

SIP