Maintenance, Upgrade, Troubleshooting – Grandstream GVC3200 Administration Guide User Manual
Page 18: Factory reset

Firmware Version 1.0.1.5
GVC3200 Administration Guide
Page 17 of 61
MAINTENANCE
UPGRADE
• Upgrade Mode
Select upgrade mode for firmware/configuration file. Users could set to TFTP, HTTP or HTTPS. The
default setting is HTTP.
• Firmware Upgrade and Provisioning
Select when to upgrade or initiate provisioning. Users can select “Always Check When Bootup”,
“When F/W Prefix/Suffix Changes” or “Skip the Firmware Check”.
• HTTP/HTTPS Username
Type the username if the HTTP/HTTPS or the config server uses the user authentication mode.
• HTTP/HTTPS Password
Type the password if the HTTP/HTTPS or the config server uses the user authentication mode.
• Firmware Server Path
Configure the server path for the firmware server.
• Config Server Path
Configure the server path for the config file server.
TROUBLESHOOTING
• IP Ping
Type in IP address or domain name in Target Host, then press red shortcut key on the remote control
to start Ping. The ping result shows in "Output Result".
• Traceroute
Fill in target host or IP address and click START to view trace route details.
• Syslog
Configure Syslog level and server address. By default syslog is turned off.
• Developer Mode
Configure whether to enable developer mode. If turned on, ADB (Android Debug Bridge) function will
be enabled on the device. The default setting is "Disabled".
FACTORY RESET
• Factory Reset
Restore to the factory settings. If check the "Clear the SD card", the GVC3200 will also format the
internal SD card storage in the device during factory resetting.