MDE-4507 Magnetic Card Encoder User’s Manual · June 2006
Page 2-1
Windows Version Requirements
Installing MCE
2 – Installing MCE
Windows Version Requirements
This MCE software will only function on PCs running Windows XP Professional.
Environmental Requirements
MCE should be located in a clean, office-type environment to ensure maximum life of the
unit. A dirty environment may cause premature failure of the reader mechanism. The
operating requirements are:
• 10
o
to 50
o
C, 20% to 80% Relative Humidity (non-condensing)
• MCE and any of the devices connected to it must not be installed in or over a hazardous
location.
Power Requirements
MCE plugs into any standard wall outlet. The power line should be free from any surges or
other electrical interference. The encoder’s power requirements are:
• 115-230 VAC +/- 10%, 47-63 HZ, 50 Watts Maximum
• All wiring must conform with the National Electrical Code (NFPA 70), the Automotive
and Marine Service Station Code (NFPA 30A), and State and Local Codes.
RS232 Wiring
MCE is provided with an interface cable (approximately 1.8 meters or 5.9 feet) for RS232
communication. Should it become necessary to construct special cables for interfacing a PC to
the MCE, the following information details the pins and signals available on the RS232 port of
the unit. Following is the connection diagram.