4 - installation, 4 – installation – Gasboy CFN Series Gilbarco CRIND PC Interface for Site Controller III User Manual
Page 15

MDE-4337G Gilbarco® CRIND® PC Interface for Site Controller III with Windows® · February 2011
Page 11
Installation
4 – Installation
To install the interface, proceed as follows.
1
Log in as the Administrator.
Note: If SC III is running, shut down the site using ALT-X to end the session.
2
Place the CRIND interface diskette in the disk drive.
3
Run a:\install from the CRIND interface disk. In the Taskbar, select Start > Run > A:\install.
A message appears “Are you connecting CRINDs to any Comm Ports?”.
4
Enter y to agree.
5
Enter the Comm Port number when prompted and press ENTER. A prompt message “Are you
going to use a GSM for DEBIT?” appears.
6
Enter the Comm Port number that is connected to the Gilbarco Security Module (GSM);
otherwise, press ENTER.
7
Edit the parameter file to match your site setup when prompted by the Install program. You
can edit this file later, in the XBIN directory, if required.
8
If you have multiple Comm Ports for CRIND devices, enter the next Comm Port number when
prompted, or press ENTER to end the program.
When the SC III is started, it will automatically start the CRIND program on the selected
ports. The session title will be CRIND session on COM x, where x is the selected Comm Port.
The parameter file is C:SC3\XBIN\CRIND.A0x, where x is the selected Comm Port.
Parameter files can be edited with any text editor.
9
Start the SC III program.
Notes: 1) If CRIND devices are not displayed, verify the following:
• Switch to the CRIND session window and press 1. If there are communication
problems, error messages must display on the screen. A message must display at
least once every 10 seconds. Press 2 to display all messages, successful or not.
• Check the number of site polls. If it is 0, the site is not polling for any CRIND
devices in the range specified in the parameter file. If some CRIND devices are
displayed and others do not, ensure that those addresses are in the range displayed
in the parameter file.
2) For the CRIND Diagnostic Card Test and Setup Procedure, refer to MDE-4185
Encore 500/Eclipse Electronics CRIND BIOS.