Hardware Connections

3 – Hardware Connections

Use a standard PC DB-9 to DB-25 Cable (Gasboy Part Number M04222A001) to connect the
selected PC Comm Port to the DB-25 Connector of the IC-485S (Gasboy Part Number
C08087). An overview of the connections is shown in

Figure 3-1

.

Figure 3-1: Hardware Wiring Connections

Both SW1 and SW2 of the IC-485S converter must be set to position 1. Connect the power
supply to the power jack of the converter and plug it in.

Set the address of each CRIND device to match the reader number in the Site Controller.
CRIND address 1 will be reader number 1. For more information, refer to

“Setup for PC-based

Application using SC III”

on

page 5

.

If the distance between the SC III and Gilbarco Distribution Box is greater than 8-feet, then the
cable is extended using an RJ-11 1:1 telephone cable or the pinout as shown in

Figure 3-2

.

This pinout allows you to hard wire the DB-9 Connector of the D-Box to the terminal block of
the converter.

Figure 3-2: Converter-to-D-Box Pinouts

Converter
TB Position

D-Box
Connection

1

2

3

4

3

7

6

2