beautypg.com

Default icr2 keypad layout, Crind bios settings, Receipt heading/footing – Gasboy CFN Series Gilbarco CRIND PC Interface for Site Controller III User Manual

Page 12

background image

Setup for PC-based Application using SC III

Gilbarco CRIND Keyboard Layout System Parameter

Page 8

MDE-4337G Gilbarco® CRIND® PC Interface for Site Controller III with Windows® · February 2011

Default ICR2 Keypad Layout

Figure 2-1: Position Numbers of the Keys on a Default ICR2 Keypad

The string entered into the SYS_PAR parameter to obtain the ICR2 keypad function
arrangement for the default ICR2 keypad is 123YY456NN789hhC0EXXuuuu.

CRIND BIOS Settings

Refer to MDE-4185 Encore 500/Eclipse Electronics CRIND BIOS or MDE-2562 CRIND
Service Manual to make the following CRIND BIOS settings:

• CRIND ID Side 1 - Match the reader number in the Site Controller (ID 1 would be reader

number 1)

• CRIND ID Side 2 - Match the reader number in the Site Controller (not used in ICR2)
• CRIND Mode - Generic (for ICR2, use Generic KIOSK)

All other BIOS settings must retain the default values. The “Change Printer Font Size” setting
(found in the printer menu) may be changed, depending on site-specific requirements.

Receipt Heading/Footing

For loading and/or changing the receipt heading and footing lines, refer to MDE-4315 CFN III
Manager’s Manual for Windows NT or MDE-4762 CFN III Manager’s Manual for Windows
XP Embedded. Using this interface, the first line of the heading loaded into the Site Controller
will affect the receipt font width. If the first heading line contains 20 characters or less, it may
wrap some of the following lines. It is recommended that the first heading line be changed to
contain “@C” (to center the text that follows it in the line), or contain more than
20 characters, if lines are being wrapped when printed.

Cancel Key when changing
CRIND BIOS Settings
(Regardless of the function
that is configured)