Saving parameter changes, Read/write a network file (-r, -w), Initialize current gasboy dial configuration (-i) – Gasboy Dial 001 User Manual
Page 11

4
Gasboy Dial 001
Credit & Debit Card Networks
Gasboy CFN Series
03/07/03
Saving Parameter Changes
To save any changes you make with the Gasboy Dial options, select Quit and answer Yes to the
save changes prompt. The program stores the information in FRAMOS.CFG and/or in the router
tables. If you do not answer Yes, none of the information you have entered will be saved! Reboot
the program to load the new configuration.
The program then runs a check on all the Gasboy Dial-related parameters. Some parameters
cannot be edited within this program, but the appropriate program is mentioned if a problem
occurs. A message will be displayed that tells you which of the parameters is in error. There is no
message displayed unless there is an error.
Read/Write a Network File (-R, -W)
Network information and card parameters can be saved to a file. You can then use the file to
reload this configuration if data is ever lost.
To save the data to a file, enter the command
GASDIAL -W
filename. Then copy the new file
and your FRAMOS.CFG file to a diskette for safe-keeping. To load or restore the data, enter
GASDIAL -R
filename. You can also use the menu options 11 and 12 as illustrated on page 16.
Initialize Current Gasboy Dial Configuration (-I)
This screen initializes the default router values and will request a configuration type. Contact
your Network Representative for the correct selection among, Generic, NBS, NBS-Growmark.
NBS has a different format for the data. If you connect to NBS but get errors on all
transactions, check this field.
GROWMARK requires a transaction # on all post-pay sales. The site is not equipped to
provide a transaction # until authorization so all post-pay sales are sent as a pre-auth/completion
pair.
Note: Do not use this command unless you want to reset all of the router values back to their
default settings. This option resets all router values to defaults by erasing whatever changes you
have entered. The network data tables affected are the card parameters, the instant-on pump
tables, and the product cross reference tables. They will need to be re-entered.
Copyright (2001) Gasboy International
Network Setup for CFN/3
Gasboy (001)
INITIALIZE NETWORK PARAMETERS
1. Generic
2. NBS
3. NBS-Growmark
Enter Item Number, Q-Quit :