View/Reset Totalizers

Electronic Totalizers

The 9800Q stores a running quantity total for each pump side. These electronic totalizers work
independent of the optional mechanical totalizers that may be installed, and are shown as
whole gallons (liters) on the displays (decimal point is shown, although it is disregarded).

The totalizer data is stored in battery-backed memory. The 9800Q is supplied with an actuator
(shown in the illustration given below) which allows you to view and reset electronic
totalizers. When the 9800Q is shipped, the actuator is attached with a tie wrap to the bracket at
the lower right of the head assembly (viewed with display panels removed). At installation or
startup, cut the tie wrap and remove actuator, and retain for future use.

To view the pump totalizers, ensure the pump handles are off and no transactions are in
progress. Locate the Gasboy dial face logo that is on the same pump side as the serial number
tag (If equipped with the rear totalizer option, the totalizer can be activated from the Gasboy
logo on either side of the pump). Touch the Gasboy logo with the actuator as shown. The
totalizer data for each pump side will be displayed for 10 seconds. If more time is needed,
touch the actuator to the logo for an additional 10-second period. To reset the electronic
totalizers, follow the disassembly procedure outlined under

Electronic Component Access,

Page 6-1

. Turn off power to the 9800Q. Close SW1-7 on the CPU PCB. Hold the actuator

against the totalizer bracket and turn the power on. The displays should change to all zeroes.
Remove the actuator and open SW1-7.

Note: Returning switch 1-7 to the open position prevents the totalizers from being reset the

next time the actuator is used to read them.

Mechanical Totalizers

Some models of 9800Q contain an optional mechanical totalizer for each pump side. Each
totalizer has eight digits; seven whole gallons and one-tenth gallon column, eight whole digits
for liters. The mechanical totalizers are located below each nozzle hook.