beautypg.com

Formax 6304 Series User Manual

Page 50

background image

48

Flap not
sufficiently
moistened.

Water level low.

Check water level,
refill if needed.

“Filling the Sealing
Liquid Reservoir” on
page 17

Brushes dry.

Check brushes,
replace if needed by
the extra soaked set.

“Operator Maintenance”
on page 43

Brushes dirty.

Check brushes, clean
if needed.

“Operator Maintenance”
on page 43

Moistening felt dry.

Check the moistening
felt, refill water tray
if needed.

“Filling the Sealing
Liquid Reservoir” on
page 17

Moistening felt dirty. Check the moistening

felt, clean if needed.

“Operator Maintenance”
on page 43

Brushes worn out.

Replace brushes.

“Operator Maintenance”
on page 43

Moistening felt worn
out.

Replace moistening
felt.

“Operator Maintenance”
on page 43

Envelope not
always ejected
from sealer.

Inserted document
too big.

Check fold settings,
adjust if needed.

“Fold Settings” on
page 24

Document not
inserted deep
enough.

Check adjustment of
envelope stop
position and fingers.

“Insert Position” on
page 49

Sealing area dirty.

Clean sealing area.

“Operator Maintenance”
on page 43

No document fed. Feeder empty.

Refill feeder.

“Filling the Document
Feeder Tray” on page 16

Separation set too
wide / too tight.

Adjust the
separation.

“Document Separation”
on page 15

Side guides set too
narrow.

Adjust the side
guides.

“Adjusting Side Guides”
on page 14

Skewed
documents fed.

Side guides set too
wide.

Adjust side guides.

“Adjusting Side Guides”
on page 14

Double
documents fed.

Separation set too
wide.

Adjust the
separation.

“Document Separation”
on page 15

Document set not
correctly inserted.

Insert position not
correct.

Check insert position. “Insert Position” on

page 49

Insert fingers not
correctly positioned.

Check insert finger
position.

“Envelope Insert
Fingers” on page 49

Address not
readable from
window

Address position not
correctly defined.

Check address
position.

“Address Position” on
page 49

Symptom

Possible cause

Remedy

Reference