beautypg.com

6 filling the sealing liquid reservoir, 7 run a job, Using an automatic job – Formax 6304 Series User Manual

Page 19: Daily mail, Englis h, Ac b

background image

17

ENGLIS

H

5. Shift envelope support B in or out, so that the

top side of the envelope lies against the dotted
line on the support.

6. Turn envelope support B so the weight of the

envelopes is distributed evenly on both sides.

3.6

Filling the Sealing Liquid

Reservoir

When you want to seal envelopes, the sealing liquid
reservoir must be filled.

1. Open the front cover A.
2. Fill the reservoir B up to lip C with sealing liquid.
3. Close the front cover A.
Before you start the job, wait approximately 5
minutes for the brushes to moisten.

If the liquid reservoir is almost empty the
touchscreen shows a message to warn you that you
should refill the reservoir.

3.7

Run a Job

To run a job:

1. From the ‘home’ menu select a job.

If you press the

OK

button, the job information

appears (see “Job Description” on page 8).

2. Load envelopes as specified in the job. Press the

Info

button for details.

3. Load the documents face up and leading, as

specified in the job. Press the

Info

button for

details.
Place the address carrier in the upper feeder.

4. Press the

1x

button to start a test run or press

the

button to start the job.

If you press the

1x

test button, the screen shows questions that help you to solve any

problems on mail set quality. If necessary this troubleshooting wizard helps you to:
-

adjust envelope position (see 7.3.1 ”Insert Position” on page 49)

-

adjust finger position (see 7.3.2 ”Envelope Insert Fingers” on page 49)

-

adjust address position (see 7.3.3 ”Address Position” on page 49)

A

C

B