Valve health – Flowserve Logix MD+ ValveSight User Manual
Page 60

ValveSight™ Diagnostics DTM Manual for Logix MD+ Positioner with HART®
FCD-
LGENSF0014-00
© Flowserve Corporation
60
 
 
Valve Health
The Valve Health page shows information about all indicators related to the condition of the 
valve. 
 
 
Status Area 
The Active Indicator area shows the status of the most relevant active indicator. The color 
of the "LED light" corresponds to the Active Indicator and the first color of the blink code 
sequence on the positioner. Generally green indicates no immediate issues. Yellow 
indicates a developing issue. Red indicates the ability to control may be compromised. A 
detailed list of the indicators is given in the 
Alarm Congfiguraion - Alarm Annunicator
page.
The Command Source field indicates weather the positioner is being controlled by digital or 
an analog (4-20 mA) command source. 
 
Indicators 
Each indicator group box may contain the following components: 
•
An "LED light" indicates health status. Warning and alarm limits (set by the
user in many cases) determine the conditions when the color will turn from 
green to yellow to red. The most sever of the indicators on this page will be 
shown in the health bar on the Dashboard. 
•
Dark Green
circle indicates a healthy condition where no attention is
needed.