Appendix B. LBC-4000

REDUNDANCY OPERATION

B.1

Introduction

The  LBC‐4000  L‐Band  Up/Down  Converter  System  can  optionally  be  configured  for  redundant 
system  operation.  This  appendix  provides  detailed  information  for  cabling  and  otherwise 
configuring the LBC‐4000 for 1:1 redundancy.  

B.2

Redundancy Operations Overview

Figure B‐1 provides a functional schematic for LBC‐4000 redundant operation.  

 

Figure B‐2 illustrates the cabling requirements for redundant operation.  

 

Note the following: 

 

o

BNC connections, where applicable, use 50Ω BNC male‐to‐male cables. 

 

o

It  is  recommended  that  all  Type  ‘N’  to  Type  ‘SMA’  cable  connections  are  best 
accomplished using a Type ‘N’ male to Type ‘SMA’ female adapter, then using Type 
‘SMA’ female‐to‐female cables.

Sect. B.3 addresses the control and configuration of an LBC‐4000 Redundancy System 

via the LBC‐4000 front panel. 

 

Sect. B.4 addresses the control and configuration of an LBC‐4000 Redundancy System 

via serial remote control.