LBC-4000 L-Band Up/Down Converter System

Revision 4

Rear Panel Connections

MN/LBC4000.IOM

3–10

3.3.1

Chassis Ground Interface

 

PROPER GROUNDING PROTECTION IS REQUIRED. The equipment must be connected 
to the protective earth connection at all times. It is therefore imperative that the unit 
is properly grounded, using the ground stud provided on the unit rear panel, during 
installation, configuration, and operation. 

 

The AC power interface provides the safety ground. 

 
 

Use  the  #10‐32  stud,  located  adjacent  to  the  power  interface,  for  connecting  a 
common chassis ground among equipment. 

 
 

3.3.2

Chassis Power Interfaces

3.3.2.1 AC Prime Power Connector

A detachable power cord, provided with the LBC‐4000, mates with the AC 
(Alternating  Current)  Prime  Power  receptacle  for  connection  to  90  to  125 
VAC, or 205 to 240 VAC power sources. 

 
 

3.3.2.2 DC Filter Input Module

 

The  DC  (Direct  Current)  Filter  Input  Module  input  voltage  is  48VDC 
nominal, ‐36 VDC minimum, ‐72VDC maximum. Table 3‐6 lists the pinouts 
for this interface. 

 
 
 
 
 

Table 3-6. DC Input Filter Module Pinouts

Pin #

Signal Name

Wire Colors

Wiring Options

A

Negative

Black

-48 VDC

0 VDC

B Ground

Green/Yellow Earth

Ground

Earth

Ground

C Positive

Red

0

VDC +48

VDC