4 select: util (utility) – Comtech EF Data LBC-4000 User Manual
Page 68
LBC-4000 L-Band Up/Down Converter System
Revision 4
Front Panel Operation
MN/LBC4000.IOM
5–12
FAULTS Æ Stored Æ Clear
Clear all stored
Faults? NO
Upon selecting Clear, you are prompted to choose NO or YES. Use the [↑][↓] arrow keys to
select your choice, and then press [ENT].
By selecting YES, the event log is cleared and you are then returned to the previous menu.
However, if there are faults present on the unit at this time, they will be re‐time‐stamped, and
new log entries will be generated.
5.2.4 SELECT: Util (Utility)
UTIL: Clock LEDtst Relay
VFD ScrSaver FWInfo ApID
Use the [←][→] arrow keys to select Clock, LEDtst, Relay, VFD, ScrSaver, FWInfo, or ApID and
then press [ENT].
The following table identifies each submenu available from the SELECT: UTIL menu branch –
typical for Converter Unit A or Unit B – its content section in this chapter, and functional
description of each submenu:
Submenu
Sect
Functional Description
Clock
5.2.4.1
Edits the date and Real-Time Clock time settings
LEDtst
5.2.4.2
Runs a diagnostic test on each of the two sets of five front panel Light-Emitting
Diodes (LEDs
Relay
5.2.4.3
Selects Fault Relay Logic
VFD
5.2.4.4
Adjusts the brightness level of the Vacuum Fluorescent Display (VFD)
ScrSaver
5.2.4.5
Screen saver
FWInfo
5.2.4.6
Displays and selects the installed internal firmware images
ApID
5.2.4.7
Use to enter an 48-character Application ID string (2 lines, 24 characters/line)