Comtech EF Data LBC-4000 User Manual
Page 85
LBC-4000 L-Band Up/Down Converter System
Revision 4
Serial-based Remote Product Management
MN/LBC4000.IOM
6–13
Parameter
Type
Command
(Instruction Code
and
Qualifier)
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes between
48 and 57)
Response to Command
(Target to controller)
Query
(Instruction Code
and qualifier)
Response to query
(Target to controller)
Retrieve Firmware
Number
N/A
Query
only.
Gets the Firmware Numbers of the unit.
Example: FRW_
BULK=FW/9965X
M&C =FW/9966X
FPGA=FW/9967X
(Where ‘X’ denotes the firmware revision letter)
N/A
FRW_
FRW_
(see Description of
Arguments for details)
Firmware Image
Selection
IMG_
1 byte
Command or query:
Selects which bulk image to boot from where x =
1=bulk image 1
2=bulk image 2
Same as command
IMG_
IMG_x
List all alarms
N/A variable Query
only.
This command retrieves a list of the stored alarms.
List All Alarms: LAA_’cr’
Confirmation: LAA_’cr’
xx yyyyyyyyyyy hh:mm:ss mm/dd/yy’cr’
xx yyyyyyyyyyy hh:mm:ss mm/dd/yy’cr’
xx yyyyyyyyyyy hh:mm:ss mm/dd/yy’cr’
“
“
“ “
“
“
“
“
xx yyyyyyyyyyy hh:mm:ss mm/dd/yy’cr’’lf’]
Where:
xx = stored fault number.
Yyyyyyyyyyy = fault description.
Hh:mm:ss = fault time.
Mm/dd/yy = fault date.
N/A
LAA_
LLA_
xx y..y h..s m..y
(see Description of
Arguments for details)
Mute State
MUT_ 5
bytes,
alpha
Command or Query.
Mutes/Unmutes the converter in the form MUT_x_yyy
where:
x = ‘A’ (Converter A) or ‘B’ (Converter B)
yyy = ON (mute) or OFF (unmute)
Example: MUT_A_OFF (Unmutes Converter A)
Same as command
MUT_x_
MUT_x_yyy
(see Description of
Arguments for details)
Online Unit
Status
N/A 1
byte
alphanumeric
Query only.
Indicates which slot is online in the form ONL_x where:
x = A or B (depending on which Converter is online).
N/A
ONL_
ONL_
(see Description of