B.3.3 config: redund (redundancy) – Comtech EF Data LBC-4000 User Manual
Page 104

LBC-4000 L-Band Up/Down Converter System
Revision 4
Appendix B
MN/LBC4000.IOM
B–6
B.3.3
CONFIG: Redund (Redundancy)
Redundancy
Mode State FrcBkup
Use the [←][→] arrow keys to select Mode, State, or FrcBkup, and then press [ENT].
CONFIG: Redund
Æ Mode
Redundancy
Control Mode = Manual
Use the [↑][↓] arrow keys to select Manual or Auto, and then press [ENT].
Note that, if you attempt to access this menu and the Redundancy Control State is selected as
Disabled, the following message displays:
Not in Redundancy
Mode!
CONFIG: Redund
Æ State
Redundancy Mode:
Control State = Enable
Use the [↑][↓] arrow keys to select Disable or Enable, and then press [ENT].
CONFIG: Redund
Æ FrcBkup
Config Manual Redund:
Force Backup NO
Use the [↑][↓] arrow keys to select YES or NO. By selecting YES, and then pressing [ENT], this
forces the redundant unit into standby mode.
Note that, if you attempt to access this menu and the Redundancy State is selected as Disabled,
the following message displays:
Not Available in
Current Mode