5.2.3 SELECT: Faults

FAULTS: Conv-A Conv-B
PwrSupA PwrSupB Stored

 
Use the [][] arrow keys to select Conv‐AConv‐B,  PwrSupAPwrSupB, or RefOsc, and then 
press [ENT] to display. Otherwise, use the [][] arrow keys to select Stored, and then press 
[ENT] when done. Otherwise, use the [][] arrow keys to select Stored, and then press [ENT] 
when done. 
 
Details about these read‐only FAULTS screens are as follows: 
 

Submenu

Screen Example

Description

Conv-A

FAULTS Cnv-A:
ifLO=OK rfLO=OK temp=OK

For Converter Unit A or B: The selected
Up/Down Converter IDU operating states are
shown, where:

ifLO= IF Lockout
rfLO = RF Lockout
temp = Operating Temp
OK = operation is normal
FT = operation is faulted.

Conv-B

FAULTS Cnv-B:
ifLO=OK rfLO=OK temp=OK

PwrSupA

FAULTS Pwr Supply A:
12V=OK 08VT=OK 05VT=OK

Where ‘X’ denotes Power Supply ‘A’ or ‘B’:
The 12V, 8V, and 5V operating states for the
selected power supply are shown, where:

OK = operation is normal
FT = operation is faulted.

PwrSupB

FAULTS Pwr Supply B:
12VT=OK 08VT=OK 05VT=OK

 
Press [ENT] or [CLR] to return to the previous menu from any read‐only FAULTS screen.  

5.2.3.1 FAULTS Æ Stored

FAULTS Stored:
View Clear

 
Use the [][] arrow keys to select View or Clear, and then press [ENT] when done. 

FAULTS Æ Stored Æ View

Fault No. 06 22:08:26
OK-IFLO_A 08/10/04

 
Use the[][] arrow keys to scroll between and view the available lists of current faults. A total 
of 100 faults can be stored in memory as they occur, and the faults are date and time stamped. 
The  stored  faults  remain  in  memory  until  a  Clear  command  is  executed.  When  the number of 
faults reaches 100, the 100

th

 fault will display an error (

ER

)