Comtech EF Data LBC-4000 User Manual
Page 106
LBC-4000 L-Band Up/Down Converter System
Revision 4
Appendix B
MN/LBC4000.IOM
B–8
B.4
Redundancy Operations via Serial Remote Control
See Chapter 6. SERIAL‐BASED REMOTE PRODUCT MANAGEMENT for detailed
information about using Serial Remote Control commands and queries for remote
Redundancy configuration, operation, and monitoring.
The following remote commands and queries are available for LBC‐4000 Redundancy operation:
Parameter Type
Command /
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes between 48 and 57)
Force Backup Unit
FBU Command
only.
Forces switchover to backup unit in Manual redundancy mode only in the form
FBU_
Redundancy Mode
RED Command
or
Query.
Used to set the chassis in redundancy mode or to query status of redundancy in
the form RED_xxx where:
xxx = ON (if redundancy is enabled) or
OFF(if redundancy is disabled)
Set Auto/Manual
Redundancy Mode
SAM Command
or
Query.
Used to set or get status of Redundancy to either Manual or Automatic mode in
the form SAM_x where:
x = a (if chassis is in Automatic Redundancy mode) or
m (if chassis is in Manual Redundancy mode)